      My friend worked in a hardware store for a couple years and he said that around Christmas time you get about a dozen people asking for these.

      • kossa@feddit.org
        link
        fedilink
        arrow-up
        3
        ·
        14 days ago

        This tale is old, and I still don’t understand what people try to accomplish with these?! Like, I know hanging like a trillion extenders behind each other is also a way to start a fire, but what are people trying to do with male-to-male cables? I’m at a loss.

        • darkdemize@sh.itjust.works
          link
          fedilink
          arrow-up
          10
          ·
          14 days ago

          They get requested around Christmas time because someone strung their lights the wrong way and now wants to connect the female end of the lights directly to the wall instead of reversing all the lights they just hung.

          • Rivalarrival@lemmy.today
            link
            fedilink
            English
            arrow-up
            5
            ·
            14 days ago

            There is a kind of person who knows how to do that safely, but that kind of person has already installed an actual load transfer switch to do it the right way.

            • TheEighthDoctor@lemmy.zip
              link
              fedilink
              English
              arrow-up
              1
              ·
              14 days ago

              I still do it, I have a lot of blackouts here, I have to close the breaker, turn on the generator and then every 15 min go downstairs to unplug the gen, and turn on the breaker to know if the electricity came back, I’m cheap but I’m also getting tired of the whole process.

        • shalafi@lemmy.world
          link
          fedilink
          English
          arrow-up
          1
          ·
          14 days ago

          I made one for the little generator at my camp. The idea was to plug the output into an outlet in my homemade shed and power it all, plus energizing an outdoor socket.

          Never got around to wiring the shed and it was easier to simply not use the other male end and wire it straight into the outside outlet. Now I can fire up the genny and have a hot outlet outside the shed.

      • billwashere@lemmy.world
        link
        fedilink
        English
        arrow-up
        1
        ·
        14 days ago

        My wife was stringing up lights on the garage wreath and had one strand turned around and wanted me to make one of these to “fix” it so it could plug in. It took a second to explain to her the other end was just going to be an exposed line voltage plug.

    • shalafi@lemmy.world
      link
      fedilink
      English
      arrow-up
      2
      ·
      14 days ago

      Made one of these on accident.

      Threw one end of the cord out in the yard and put a new male plug on the other end. Went to plug my saw in and found a male end. Silly me! So I swapped the cord around the threw the other end in the yard. Went to plug my saw in and found a male end. Stood there a minute trying to figure out what the hell was going on.

      • OhStopYellingAtMe@lemmy.world
        link
        fedilink
        arrow-up
        0
        ·
        14 days ago

        I just recently did the same with a set of patio lights. Was shortening a set of lights which hang over my porch. Measured out the length I needed, cut the cord, attached a new female end. Went to plug the other end in… also female!

        • shalafi@lemmy.world
          link
          fedilink
          English
          arrow-up
          1
          ·
          14 days ago

          Female-female is OK. It’s male-male that’s hot. Know what I mean? Nudge, nudge, wink, wink.

    • yesman@lemmy.world
      link
      fedilink
      arrow-up
      0
      ·
      14 days ago

      You see, if the device from the meme was ever plugged in, it’d blow the breaker immediately. This male to male cord, if plugged into two outlets would do nothing.

    • billwashere@lemmy.world
      link
      fedilink
      English
      arrow-up
      0
      ·
      14 days ago

      If I’m not mistaken plugging this in to the same outlet won’t do anything. And as far as back feed problems couldn’t you just shut off the the main breaker, i.e. where the power comes into the house?

      • 2ndDegreeOWO@lemmy.world
        link
        fedilink
        arrow-up
        1
        ·
        14 days ago

        It will either instantly trip the breaker or do absolutely nothing, depending on how it’s wired internally.

        The real danger comes from when only one end is plugged in, though. With only one end plugged in, the other end becomes a 120V cattle prod.

    • y0kai@anarchist.nexus
      link
      fedilink
      English
      arrow-up
      2
      ·
      14 days ago

      not an electrician but am in the US and have blown an entire middle school gymnasium with a paperclip lmao

      Gym teachers hate this one simple trick

    • tetris11@feddit.uk
      link
      fedilink
      English
      arrow-up
      0
      ·
      14 days ago

      It’s about the current though no?

      UK we have 32A / 6A (e.g. lighting) circuit breakers, but our individual devices are fused at the plug at 1A / 3A / 6A depending on load. A single house has maybe 10 fuses max at the consumer unit.

      US they have more circuit breakers, with breakers at 3A / 6A (?) without any fuses on their device plugs, so they have to routinely change the the tiny circuit breaker at the consumer unit, but because of this limitation, they typically have double the number of circuit breakers at the unit ?

      In the above example, the short circuit would still happen through the plug and not before it, so in the UK we would just chuck the plug fuse

      (Asking, because I genuinely don’t know)

    • shininghero@pawb.social
      link
      fedilink
      arrow-up
      0
      ·
      14 days ago

      Not just the house fuse. They’d arc flash their eyeballs and probably develop tinnitus.
      Some Americans would be dead in an afternoon if they had access to 240 at every outlet, and others would do it on purpose to try and get a settlement payout. If you ever wonder why there’s so many warning labels, this is why.

      • y0kai@anarchist.nexus
        link
        fedilink
        English
        arrow-up
        1
        ·
        14 days ago

        at least all the european plugs i’ve seen are responsibly built. They expose the contacts on the very end of the little needly things so you can’t just casually touch them while plugging something in. Here, the entire shaft is metal and you can just like, touch both of them with the plug half plugged in.

      • starman2112@sh.itjust.works
        link
        fedilink
        arrow-up
        1
        ·
        14 days ago

        This is a continuous line of rather thick metal. It wouldn’t arc or electrocute anyone, it would get a fraction of a degree warmer before the circuit breaker tripped

  • neidu4@piefed.social
    link
    fedilink
    English
    arrow-up
    3
    arrow-down
    1
    ·
    14 days ago

    It’d be alright if made from plastic.

    And yes, I’ve chosen to disregard that something between the connector and the socket theoretically makes it more unsafe; US sockets are an awful design to begin with, so it doesn’t make much of a difference.

  • InFerNo@lemmy.ml
    link
    fedilink
    arrow-up
    1
    ·
    14 days ago

    This is oddly relevant to something I was searching. i’m looking for both the type of material and method of bending to achieve a similar end result (of bent wire). I promise I won’t gouge the outlets. Can anyone shine a light?