I wanted to share this opinion on Hackaday about a topic that is the usefulness of a something that has become ubiquitous relatively fast.

This techonolgyy has a lot of potential, what do you think?

  • Dale'sDeadBug@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    5
    ·
    10 months ago

    I love PoE, but there are some hard limitations to that idea. Mainly cost per meter of cable, but also in the amount of runs that would need to be completed to accomplish that. I cant splice two ethernet cables together and run one to a nearby light or other device without a switch, which means more equipment or more cable to make it work. Also, being 48v, it will have a lower overall efficiency compared to direct wiring with 110-220v, especially with the higher resistance of ethernet vs 14ga romex. That being said, I’d love to see 48v dc in home outlets.

    • Flipper@feddit.de
      link
      fedilink
      English
      arrow-up
      2
      ·
      10 months ago

      Oh boy do I have something for you. The single pair ethernet standards. Connect 8 devices on the same line as a bus.

      • Dale'sDeadBug@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        1
        ·
        10 months ago

        Didn’t realize that was part of the spec. But wouldn’t that be 4 devices? 2 wires per device for tx/rx and power +/-.

        • Flipper@feddit.de
          link
          fedilink
          English
          arrow-up
          3
          ·
          edit-2
          10 months ago

          No. It’s a single twisted pair wire to connect at least 8 devices over a minimum distance of 25m. However the speed is only 10MBit. The spec is called base10-t1s

      • frezik@midwest.social
        link
        fedilink
        English
        arrow-up
        1
        ·
        10 months ago

        That would only allow PoE+, which limits devices to 25.5W. Speed would be limited to 100Mbps. Still enough for lights, though.

    • frezik@midwest.social
      link
      fedilink
      English
      arrow-up
      2
      ·
      10 months ago

      If we’re talking about hiring someone to run AC wires, then the cost of extra equipment can be offset by the labor costs.

      (I have definitely hired a master electrician for every outlet added to my house. Definitely.)